5kW Fuel Cell Stack T-Series
This fuel cell stack is actually not just one stand-alone fuel cell stack, but is actually two of the T-2,500W units combined in order to achieve a combined 5,000W. While this fuel cell system produces more power than the first product in this series it retains all of the location deployment advantages of the first product, including being environmentally friendly. In stationary applications the T-5000 is capable of providing all of the electricity a research building and supporting habitational structures such an outpost may have, but if additional power is needed then it can be supplemented by solar panels or a wind turbine. With its need for only air cooling and high-power output, this product is an ideal solution to a wide variety of commercial and educational needs.
5000W Air Cooled Fuel Cell Stack
Additional Information
This fuel cell system comes with a controller, FC connector, RS232 cable, FC +/- cables, output +/- cables, pressure regulator, 6mm PTFE tube, Ferrule Connectors, and a hydrogen sensor.
Because we are unable to keep this product in stock, please fill out a quote request form here so that we can get into touch with you and help you to place an order for this fuel cell stack. We can also answer any questions you may have and provide proper delivery expectations. Please feel free to use the quote request form for this fuel cell stack and provide us with information regarding the intended use of this product. That way we can work with you on helping you to order any additional components that may be needed.
List of T-5000 components:
2 x 2500W fuel cell stack
2 x 2500W controller
2 x fuel cell connector
2 x RS232 cable
2 x FC +/- cables
2 x Output +/- cables
2 x pressure regulator
4 x 8mm PTFE tube (1m)
40 x ferrule connectors
2 x hydrogen sensor
1 x set of cables connecting the modules
5000W Air Cooled Fuel Cell Stack Quick Product Facts
Hydrogen Pressure
Hydrogen must be fed into the fuel cell stack at a pressure of 0.55 to 0.75bar.
Ambient Temperature
The fuel cell stack operates best in a temperature ranging from 0 to 40° C.
FC Stack Weight
The stack (including fan and casing) weighs 178lbs / 80.6kg.
System Efficiency
At peak power the efficiency of the system is 42%.
Hydrogen Purity
A fuel of gaseous hydrogen at a minimum purity level of 99.995% is required.
Voltage Output
The voltage can be adjusted to between 43.2 and 57.6 volts direct current.
Packing Information
T-1000 | T-2500 | T-3000 | T-5000 | T-10000 | |
---|---|---|---|---|---|
Power rating | 0 to 1000 W @ 20°C and 101.3 kPa | 0 to 2500 W @ 20°C and 101.3 kPa | 0 to 3000 W @ 20°C and 101.3 kPa | 0 to 5000 W @ 20°C and 101.3 kPa | 0 to 5000 W @ 20°C and 101.3 kPa |
Current Rating | 0 to 19A @54V | 0 to 47A @54V | 0 to 56A @54V | 0 to 47A x 2 @54V | 0 to 47A x 4 @54V |
Voltage Adjustable | 43.2 to 57.6 VDC | 43.2 to 57.6 VDC | 43.2 to 57.6 VDC | 43.2 to 57.6 VDC | 43.2 to 57.6 VDC |
Voltage Ripple | ±1V | ±1V | ±1V | ±1V | ±1V |
Controller Dimension (WxDxH) | 430mm x 550mm x 88mm | 430mm x 550mm x 88mm | 430mm x 550mm x 150mm | (430mm x 550mm x 88mm) x 2 | (430mm x 550mm x 88mm) x 4 |
Stack Dimension (WxDxH) | 430mm x 550mm x 88mm | 430mm x 550mm x 356mm | 430mm x 550mm x 356mm | (430mm x 550mm x 356mm) x 2 | (430mm x 550mm x 356mm) x 4 |
Controller Weight | 10 kg | 13.5 kg | 15 kg | 13.5 x 2 kg | 13.5 x 4 kg |
Stack Weight | 18 kg | 40.3 kg | 40.3 kg | 40.3 x 2 kg | 40.3 x 4 kg |
Ambient temeprature * | -10⁰C to +45⁰C standard | -10⁰C to +45⁰C standard | -10⁰C to +45⁰C standard | -10⁰C to +45⁰C standard | -10⁰C to +45⁰C standard |
Recommended cold start temp | More than 5⁰C | More than 5⁰C | More than 5⁰C | More than 5⁰C | More than 5⁰C |
Relative Humidity | 0‐95% Non‐Condensing | 0‐95% Non‐Condensing | 0‐95% Non‐Condensing | 0‐95% Non‐Condensing | 0‐95% Non‐Condensing |
Communications | RS232 | RS232 | RS232 | RS232 | RS232 |
Standby Power Consumption | Approximately<3% at peak power (DC) | Approximately<3% at peak power (DC) | Approximately<3% at peak power (DC) | Approximately<3% at peak power (DC) | Approximately<3% at peak power (DC) |
Reactants | Hydrogen and Air | Hydrogen and Air | Hydrogen and Air | Hydrogen and Air | Hydrogen and Air |
Cooling | Air (integrated cooling fan) | Air (integrated cooling fan) | Air (integrated cooling fan) | Air (integrated cooling fan) | Air (integrated cooling fan) |
H2 inlet pressure | 0.55-0.75bar | 0.55-0.75bar | 0.55-0.75bar | 0.55-0.75bar | 0.55-0.75bar |
Hydrogen purity | ≧99.95% dry H2 | ≧99.95% dry H2 | ≧99.95% dry H2 | ≧99.95% dry H2 | ≧99.95% dry H2 |
Consumption | ≦0.78 Nm3/kWh (Average at max. load) | ≦0.78 Nm3/kWh (Average at max. load) | ≦0.78 Nm3/kWh (Average at max. load) | ≦0.78 Nm3/kWh (Average at max. load) | ≦0.78 Nm3/kWh (Average at max. load) |
Start up time | ≦2minute at ambient temperature | ≦2minute at ambient temperature | ≦2minute at ambient temperature | ≦2minute at ambient temperature | ≦2minute at ambient temperature |
Efficiency of system | ≧42% at peak power | ≧42% at peak power | ≧42% at peak power | ≧42% at peak power | ≧42% at peak power |
Temperature De-rating | 1.25% per °C over 40°C | 1.25% per °C over 40°C | 1.25% per °C over 40°C | 1.25% per °C over 40°C | 1.25% per °C over 40°C |
Altitude De-rating | 3.5% per 500m over 1000m | 3.5% per 500m over 1000m | 3.5% per 500m over 1000m | 3.5% per 500m over 1000m | 3.5% per 500m over 1000m |
Max. noise | Normal operation: <70 dBa at 1="1"> | Normal operation: <70 dBa at 1="1"> | Normal operation: <70 dBa at 1="1"> | Normal operation: <70 dBa at 1="1"> | Normal operation: <70 dBa at 1="1"> |
Storage Temperature | ﹣20⁰ to + 50⁰C Standard | ﹣20⁰ to + 50⁰C Standard | ﹣20⁰ to + 50⁰C Standard | ﹣20⁰ to + 50⁰C Standard | ﹣20⁰ to + 50⁰C Standard |
* additional heating needed when temperature less than 0⁰C, during operation