Need help?

1kW Fuel Cell T-Series

This kW fuel cell stack is the entry-level product in the T Series of fuel cell stacks which are primarily geared towards stationary applications. While this fuel cell stack can be used in a stationary setting like off-grid living, it is focused more on remote commercial locations. Cellular tower sites as well as marine and rail monitoring sites often are located in rural areas, and it is these rural locations that this fuel cell stack is built for. Another benefit to the T Series is that the fuel cells use hydrogen to create energy, which reduces the amount of space that needs to be enclosed since hydrogen is weather agnostic. There is no need for any special structures or accommodations needed to handle a hazardous substance, like diesel, because hydrogen is non-toxic and environmentally friendly.

T-Series-2

1000W Fuel Cell Stack T Series

Additional Information

T Series fuel cell systems typically come with a controller, FC connector, RS232 cable, FC +/- cables, output +/- cables, pressure regulator, 6mm PTFE tube, Ferrule Connectors, and a hydrogen sensor.

Customers are required to fill out quote request forms for this fuel cell stack, since Horizon carries a limited number of these at any given time. By submitting the form, we will be able to set proper delivery expectations as well as work with you to create a package to ensure you have all of the fuel cell stack accessories in order to facilitate project development.

List of T-1000 components:

1 x 1000W fuel cell stack

1 x 1000W controller

1 x fuel cell connector

1 x RS232 cable

1 x FC +/- cables

1 x pressure regulator

2 x 6mm PTFE tube (1m)

20 x ferrule connectors

1 x hydrogen sensor

1000W Fuel Cell Stack T Series Quick Product Facts

Pressure

Hydrogen Pressure

Hydrogen must be fed into the fuel cell stack at a pressure of 0.55 to 0.75bar.

Temperature

Ambient Temperature

The fuel cell stack operates best in a temperature ranging from 0 to 40° C.

weight

FC Stack Weight

The stack (including fan and casing) weighs 40lbs / 18kg.

efficiency

System Efficiency

At peak power the efficiency of the system is 42%.

1

Hydrogen Purity

A fuel of gaseous hydrogen at a minimum purity level of 99.995% is required.

2

Voltage Output

The voltage can be adjusted to between 43.2 and 57.6 volts direct current.

Packing Information

 

  T-1000 T-2500 T-3000 T-5000 T-10000
Power rating 0 to 1000 W @ 20°C and 101.3 kPa 0 to 2500 W @ 20°C and 101.3 kPa 0 to 3000 W @ 20°C and 101.3 kPa 0 to 5000 W @ 20°C and 101.3 kPa 0 to 5000 W @ 20°C and 101.3 kPa
Current Rating 0 to 19A @54V 0 to 47A @54V 0 to 56A @54V 0 to 47A x 2 @54V 0 to 47A x 4 @54V
Voltage Adjustable 43.2 to 57.6 VDC 43.2 to 57.6 VDC 43.2 to 57.6 VDC 43.2 to 57.6 VDC 43.2 to 57.6 VDC
Voltage Ripple ±1V ±1V ±1V ±1V ±1V
Controller Dimension (WxDxH) 430mm x 550mm x 88mm 430mm x 550mm x 88mm 430mm x 550mm x 150mm (430mm x 550mm x 88mm) x 2 (430mm x 550mm x 88mm) x 4
Stack Dimension (WxDxH) 430mm x 550mm x 88mm 430mm x 550mm x 356mm 430mm x 550mm x 356mm (430mm x 550mm x 356mm) x 2 (430mm x 550mm x 356mm) x 4
Controller Weight 10 kg 13.5 kg 15 kg 13.5 x 2 kg 13.5 x 4 kg
Stack Weight 18 kg 40.3 kg 40.3 kg 40.3 x 2 kg 40.3 x 4 kg
Ambient temeprature * -10⁰C to +45⁰C standard -10⁰C to +45⁰C standard -10⁰C to +45⁰C standard -10⁰C to +45⁰C standard -10⁰C to +45⁰C standard
Recommended cold start temp More than 5⁰C More than 5⁰C More than 5⁰C More than 5⁰C More than 5⁰C
Relative Humidity 0‐95% Non‐Condensing 0‐95% Non‐Condensing 0‐95% Non‐Condensing 0‐95% Non‐Condensing 0‐95% Non‐Condensing
Communications RS232 RS232 RS232 RS232 RS232
Standby Power Consumption Approximately<3% at peak power (DC) Approximately<3% at peak power (DC) Approximately<3% at peak power (DC) Approximately<3% at peak power (DC) Approximately<3% at peak power (DC)
Reactants Hydrogen and Air Hydrogen and Air Hydrogen and Air Hydrogen and Air Hydrogen and Air
Cooling Air (integrated cooling fan) Air (integrated cooling fan) Air (integrated cooling fan) Air (integrated cooling fan) Air (integrated cooling fan)
H2 inlet pressure 0.55-0.75bar 0.55-0.75bar 0.55-0.75bar 0.55-0.75bar 0.55-0.75bar
Hydrogen purity ≧99.95% dry H2 ≧99.95% dry H2 ≧99.95% dry H2 ≧99.95% dry H2 ≧99.95% dry H2
Consumption ≦0.78 Nm3/kWh (Average at max. load) ≦0.78 Nm3/kWh (Average at max. load) ≦0.78 Nm3/kWh (Average at max. load) ≦0.78 Nm3/kWh (Average at max. load) ≦0.78 Nm3/kWh (Average at max. load)
Start up time ≦2minute at ambient temperature ≦2minute at ambient temperature ≦2minute at ambient temperature ≦2minute at ambient temperature ≦2minute at ambient temperature
Efficiency of system ≧42% at peak power ≧42% at peak power ≧42% at peak power ≧42% at peak power ≧42% at peak power
Temperature De-rating 1.25% per °C over 40°C 1.25% per °C over 40°C 1.25% per °C over 40°C 1.25% per °C over 40°C 1.25% per °C over 40°C
Altitude De-rating 3.5% per 500m over 1000m 3.5% per 500m over 1000m 3.5% per 500m over 1000m 3.5% per 500m over 1000m 3.5% per 500m over 1000m
Max. noise Normal operation: <70 dBa at 1="1"> Normal operation: <70 dBa at 1="1"> Normal operation: <70 dBa at 1="1"> Normal operation: <70 dBa at 1="1"> Normal operation: <70 dBa at 1="1">
Storage Temperature ﹣20⁰ to + 50⁰C Standard ﹣20⁰ to + 50⁰C Standard ﹣20⁰ to + 50⁰C Standard ﹣20⁰ to + 50⁰C Standard ﹣20⁰ to + 50⁰C Standard

* additional heating needed when temperature less than 0⁰C, during operation

T series